Reliable fully automatic graphite furnace analysis
Perfect safety protection measures
Advanced and reliable electronic design
Easy and practical analysis software
|
Main Specification |
Wavelength range | 190-900nm |
| Wavelength accuracy | Better than ±0.25nm | |
| Resolution | Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. | |
| Baseline stability | 0.004A/30min | |
| Background correction | The D2 lamp background correction capability at 1A is better than 30 times.The S-H background correction capability at 1.8A is better than 30 times. | |
|
Light Source System |
Lamp turret |
Motorized 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.) |
| Lamp current adjustment | Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA. | |
| Lamp power supply mode | 400Hz square wave pulse;100Hz narrow square wave pulse + 400Hz wide square pulse wave. | |
|
Optical System |
Monochomator |
Single beam, Czerny-Turner design grating monochromator |
|
Grating |
1800 l/mm | |
|
Focal length |
277mm | |
|
Blazed Wavelength |
250nm | |
|
Spectral Bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.2nm, auto switch over | |
|
Flame Atomizer |
Burner |
10cm single slot all-titanium burner |
|
Spray chamber |
Corrosion resistant all-plastic spray chamber. | |
|
Nebulizer |
High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min | |
| Emission burner provided | ||
|
Graphite Furnace |
Temperature range |
Room temperature~3000ºC |
|
Heating rate |
2000℃/s | |
| Graphite tube dimensions | 28mm (L) x 8mm (OD) | |
|
Characteristic mass |
Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g | |
|
Precision |
Cd≤3%, Cu≤3%, Mo≤4% | |
|
Detection and Data Processing System |
Detector |
R928 photomultiplier with high sensitivity and wide spectral range. |
|
Software |
Under Windows operating system | |
|
Analytical method |
Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. | |
| Repeat times | 1~99 times, automatic calculation of mean value, standard deviation and relative standard deviation. | |
|
Multi-task Functions |
Sequential determination of multi-elements in the same sample. | |
|
Condition reading |
With model function | |
|
Result printing |
Measurement data and final analytical report printout, editing with Excel. | |
| Standard RS-232 serial port communication | ||
| Graphite Furnace Autosampler | Sample tray capacity | 55 sample vessels and 5 reagent vessels |
|
Vessel material |
Polypropylene | |
|
Vessel volume |
3ml for sample vessel, 20ml for reagent vessel | |
|
Minimum sampling volume |
1μl | |
|
Repeatable sampling times |
1~99 times | |
|
Sampling system |
Accurate dual pump system, with 100μl and 1ml injectors. | |
|
Characteristic Concentration and Detection Limit |
Air-C2H2 flame |
Cu: Characteristic concentration ≤ 0.025 mg/L, Detection limit≤0.006mg/L; |
|
Function Expansion |
Hydride vapor generator can be connected for hydride analysis. | |
|
Dimensions and Weight |
Main unit |
107X49x58cm, 140kg |
|
Graphite furnace |
42X42X46cm, 65kg | |
|
Autosampler |
40X29X29cm, 15kg | |